WickRight Roof Vent allows the interstitial space beneath the plywood roof deck to exhaust condensation, significantly extending the life of roofing and structural components. Roof Vent provides continuous passive ventilation to wet truss ends embedded in masonry pockets; allowing the truss ends to dry, extending the useful life of some trusses. Click on pictures below to enlarge.
Schedule a building evaluation
See our Truss Reinforcement bracket system below.
Click images below to enlarge.
WickRight Flat Roof Vent exhausts heat from under roof membranes and interstitial roof space, eliminates condensation build-up and significantly extends the useful life of roof membranes, plywood sheathing and insulation. Our Roof Vent provides an interior rain screen for walls, which manages moisture intrusion from the exterior, allows internal moisture vapor to exit. WickRight Flat Roof Vent separates the roof space from the masonry to keep it dry.
WickRight Flat Roof Vent allows the interstitial space beneath the plywood roof deck to exhaust condensation, and re-directs moisture intrusion from the masonry wall to the exterior, away from the roof system.
WickRight Flat Roof Vent allows wet truss ends embedded in wet masonry pockets to dry. Unfortunately, some trusses may be damaged beyond saving and need to be replaced.
See our Truss Reinforcement bracket system
Click on pictures below to enlarge
If your project smells funky, have everyone wear respirators to avoid inhaling dangerous mold spores.
Most of the damaged trusses embedded in wet masonry walls that we have uncovered, were candidates for truss reinforcement and did not need to be replaced.
Our construction division, WickRight General Contracting, removes mortar and spray foam insulation from trusses, then apply, a combination moldicide/hardener/sealer, to the damaged trusses. If necessary they "sister" trusses with structural plywood to add strength per recommendations of licensed structural engineers. Finally, they install our reinforcement brackets.
If a building smells funky, wear a respirator to avoid inhaling dangerous mold spores. We have found that about 50% of the rotted truss ends embedded in wet masonry wall pockets can be reinforced and saved.
See WickRight Truss Reinforcement System
If your project has damaged trusses caused by wet masonry walls or condensation production under the roof membrane, call us.
Truss reinforcement and/or replacement takes time. No need to open and close the roof each day – Rent a 365 Construction Tent.
365 Construction Tents are specifically designed to protect flat roofs with parapets from rain, snow and wind. 365 Tents save you time, money and allows scheduling without concern for the weather.
Custom Configurations for larger buildings, stairwell buildings and balconies are available. Call for details.
Click on pictures below to enlarge.
Have a project with truss reinforcement or replacement?
Rent a 365 Construction Tent - specifically designed to protect low-slope roofs with parapets. Tenting eliminates opening and closing the roof each day, saves you time, money and allows scheduling without concern for weather.
Click on pictures below to enlarge.
Above – WickRight Capstone Vented Drip Edge and Vented Receiver Clip (top of parapet) and WickRight Flat Roof Vent installed against the parapet wall and into the roof system.
Roof Vent can be installed with or without any parapet ventilation devices, but we recommend combining systems to gain significant drying effect for the wall and prevent any additional moisure intrusion.
Installing Roof Vent plastic extension beyond the roof system, down to the drywall if possible, will provide maximum drying to the wall and roof system, and beyond the through wall flashing.
Our Flat Roof Vent allows heat to exit from under the roof membrane, extending the useful life of existing roof materials..
Cost: Installing WickRight Flat Roof Vent as shown adds approximately 6% to the material cost of a new roof.
Labor: Installation requires 2 additional steps adding 1-2 days for 2 roofers to the project timeline for a standard size residential roof. 20' x 70' in Chicago
Modified Bitumen can be torched directly to the 1/2" Polyiso Coverboard side of Roof VRS. No primer needed. Also, no Roof termination is needed if WickRight Counter Flashing and Bug Screen is installed.
Installing our Offset Counter Flashing and Bug Screen above the WickRight Flat Roof Vent is required. It protects the exhaust portals from rain and insects.
Our custom Counter Flashing slips into the WickRight Vented Receiver Clip installed above the Flat Roof Vent in this picture.
Simply slide bug screen behind the counter flashing and fasten through the counter flashing into the parapet wall.
WickRight General Contracting has been repairing wet buildings since 2012.
There's a lot to know! Moisture intrusion complex and effects each building differently. We're happy to help you avoid missteps that we've already made and provide guidance to keep your project streamlined.
We also offer HOA presentation assistance to save everyone a lot of time.
WickRight Parapet Vent®, WickRight Coping VRS™, WickRight Capstone VRS™, WickRight Clip Coping VRS™, WickRight Roof VRS™, WickRight Hip & Valley VRS™ and WickRight Perimeter VRS™ are patented products and trademarks owned by WickRight Inc. WickRight Parapet Vent® is a registered trademark of WickRight, Inc. WickRight™, WickRight VRS and Vapor Release Systems™, Buildings Breathe Right™ are trademarks of WickRight Inc.
All Rights Reserved | WickRight Inc. | Website design by Knight Advertising Design, Inc.